Gocator 2600 Series
The Gocator 2600 series consists of the following models:
| MODEL | 2630 | 2640 | 2650 | 2670 | 2690 |
|---|---|---|---|---|---|
|
Data Points / Profile |
4200 | 4200 | 4200 | 4200 | 4200 |
|
Resolution X (µm) (Profile Data Interval) |
18 - 33 | 28 - 46 | 47 - 104 | 67 - 197 | 124 - 550 |
| Linearity Z (+/- % of MR) | 0.03 | 0.04 | 0.04 | 0.05 | 0.08 |
| Repeatability Z (µm) | 0.30 | 1.00 | 2.70 | 10.00 | TBD |
|
Clearance |
110 | 170 | 330 | 495 | 325 |
|
Measurement |
130 | 190 | 475 | 1060 | 1550 |
| Field of View (FOV) (mm) | 71 - 135 |
105 - 198 | 190 - 430 |
272 - 817 |
385 - 2000 |
| Laser Classes |
2, 3R, 3B (blue, 405 nm) |
2, 3R, 3B (blue, 405 nm) |
2, 3R, 3B (blue, 405 nm) |
2, 3R, 3B (blue, 405 nm) |
2, 3R (red, 660 nm) |
| Dimensions (mm) | 55 x 105 x 165 | 55 x 105 x 195 | 55 x 105 x 280 | 55 x 105 x 280 | 55 x 105 x 280 |
| Weight (kg) | 1.34 | 1.48 | 2.12 | 2.12 | 2.12 |
The following diagram illustrates some of the terms used in the table above.
Specifications stated are based on standard laser classes. Linearity Z and Repeatability Z may vary for other laser classes.
All specification measurements are performed on LMI’s standard calibration target (a diffuse, painted white surface).
Linearity Z is the worst case difference in average height measured, compared to the actual position over the measurement range.
Resolution X is the distance between data points along the laser line.
Repeatability Z is measured with a flat target at the middle of the measurement range. It is the 95% confidence variation of the average height over 4096 frames. Height values are averaged over the full FOV.
See Resolution and Accuracy for more information.
|
ALL 2600 SERIES MODELS |
|
|---|---|
|
Scan Rate |
300 to 5000 Hz |
| Interface | Gigabit Ethernet |
| Inputs | Differential Encoder, Laser Safety Enable, Trigger |
| Outputs | 2x Digital output, RS-485 Serial (115 kBaud) |
| Housing | Gasketed metal enclosure, IP67 |
| Input Voltage (Power) | +24 to +48 VDC (15 W); Ripple +/- 10% |
| Operating Temp. | 0 to 50° C |
| Storage Temp. | -30 to 70° C |
| Vibration Resistance | 10 to 55 Hz, 1.5 mm double amplitude in X, Y, and Z directions, 2 hours per direction |
| Shock Resistance | 15 g, half sine wave, 11 ms, positive and negative for X, Y, and Z directions |
Mechanical dimensions, CD/FOV/MR, and the envelope for each sensor model are illustrated on the following pages.